独家

6kV~35kV变压器能效限定值及能效等级

41
0
2022-11-24
简介
ICS29.180K41CEEIA中国电器工业协会标准T/CEEIA258-20166kV~35kV变压器能效限定值及能效等级Minimumallowablevaluesofenergyefficiencyandenergyefficiencygradesfor6kV~35kVtransformers2016-12-26发布2016-12-26实施中国电器工业协会发布T/CEEIA258—2016I目次前言................................................................................II引言...............................................................................III1范围..............................................................................12规范性引用文件....................................................................13术语和定义........................................................................24技术要求..........................................................................25试验方法..........................................................................36变压器的能效等级、能效限定值、节能评价值..........................................3T/CEEIA258—2016II前言本标准由中国电器工业协会批准、发布。版权归中国电器工业协会

文档内容部分截取

ICS29.180K41CEEIA中国电器工业协会标准T/CEEIA258-20166kV~35kV变压器能效限定值及能效等级Minimumallowablevaluesofenergyefficiencyandenergyefficiencygradesfor6kV~35kVtransformers2016-12-26发布2016-12-26实施中国电器工业协会发布T/CEEIA258—2016I目次前言................................................................................II引言...............................................................................III1范围..............................................................................12规范性引用文件....................................................................13术语和定义........................................................................24技术要求..........................................................................25试验方法..........................................................................36变压器的能效等级、能效限定值、节能评价值..........................................3T/CEEIA258—2016II前言本标准由中国电器工业协会批准、发布。版权归中国电器工业协会所有,任何组织和个人未经中国电器工业协会许可,不得印刷、销售。考虑到本标准中某些条款可能涉及的专利,中国电器工业协会不负责对任何类别专利权的鉴别。本标准按照GB/T1.1—2009给出的规则起草。本标准由中国电器工业协会负责起草。本标准在GB20052-2013《三相配电变压器能效限定值及能效等级》标准的基础上结合变压器的实际使用情况,并征求来自全国变压器标准化技术委员会、相关科研院所、认证机构和变压器制造企业等专家的意见后制订完成。本标准由中国电器工业协会标准化工作委员会提出并归口。本标准参加起草单位:中国电器工业协会、机械工业北京电工技术经济研究所、沈阳变压器研究院股份有限公司、苏州电器科学研究院股份有限公司、中国电力科学研究院、海鸿电气有限公司、天津天能变压器有限公司、杭州钱江电气集团股份有限公司、西安西电变压器有限责任公司、保定天威集团特变电气有限公司、江苏华鹏变压器有限公司、上海置信电气股份有限公司、顺特电气设备有限公司、三变科技股份有限公司、中国质量认证中心、电能(北京)产品认证中心有限公司、国家变压器质量监督检验中心、国家电器产品质量监督检验中心、华信技术检验有限公司、新华都特种电气股份有限公司、吴江变压器有限公司、西电济南变压器股份有限公司、成都西电蜀能电器有限责任公司、北京科锐配电自动化股份有限公司、北京博锐高新电气科技发展中心、金三角电力科技股份有限公司、浙江江山变压器股份有限公司、广西柳州特种变压器有限责任公司。本标准主要起草人:郭振岩、陈奎、章忠国、侯垚、梁庆宁、李明智、田贵书、刘军、宓传龙、张四民、赵峰、赵文俊、吴彬、李霞、黄建华、吴珊、赵刚、韩筛根、王蔚林、吕祥鹏、黄立国、宗宝峰、梅成、顾建伟、梁雅仲、李银行、陈培智、马萍香、江春惠、林灿华、王士宝、顾雪军、陈慧争、顾小虎、李静、单杨雨、徐志坚、蔡新华、马桂芬。本标准在实施过程中,如发现需要修改或补充之处,请将意见和有关资料寄给中国电器工业协会标准化工作委员会秘书处,以便修订工作。T/CEEIA258—2016III引言本标准根据工业和信息化部、国家质检总局和国家发改委《配电变压器能效提升计划(2015-2017年)》的要求,由工业和信息化部节能与综合利用司提出。本标准是对GB20052-2013《三相配电变压器能效限定值及能效等级》的补充和完善。本标准所指变压器的种类、电压等级、额定容量、联结组别、短路阻抗与GB/T6451-2015《油浸式电力变压器技术参数和要求》、JB/T10317-2014《单相油浸式配电变压器技术参数和要求》和GB/T10228-2015《干式电力变压器技术参数和要求》完全相同。T/CEEIA258—201616kV~35kV变压器能效限定值及能效等级1范围本标准是对GB20052-2013《三相配电变压器能效限定值及能效等级》的补充和完善,补充和增加了6kV~35kV单相、三相油浸式、干式配电和电力变压器(以下简称变压器)的能效限定值、能效等级、节能评价值和试验方法。本标准规定了变压器的空载损耗和负载损耗值,并增加了与能效等级对应的变压器损耗水平代号。本标准适用范围见表1表1:6kV~35kV变压器能效限定值和能效等级标准适用范围铁心材料电压等级(kV)三相单相油浸式电工钢带6、10无励磁调压配电变压器无励磁调压配电变压器无励磁调压电力变压器——有载调压配电变压器20无励磁调压配电变压器无励磁调压配电变压器35无励磁调压配电变压器———无励磁调压电力变压器有载调压电力变压器非晶合金6、10无励磁调压配电变压器无励磁调压配电变压器20无励磁调压配电变压器——35无励磁调压配电变压器干式电工钢带6、10无励磁调压配电变压器———————无励磁调压电力变压器有载调压配电变压器20无励磁调压配电变压器35无励磁调压配电变压器无励磁调压电力变压器有载调压电力变压器非晶合金6、10无励磁调压配电变压器—本标准不适用于充气式变压器2规范性引用文件下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅所注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。GB1094.1电力变压器第1部分:总则GB1094.11电力变压器第11部分:干式变压器GB20052-2013三相配电变压器能效限定值及能效等级T/CEEIAXX—20162GB/T2900.95电工术语变压器、互感器、调压器和电抗器GB/T6451-2015油浸式电力变压器技术参数和要求GB/T10228-2015干式电力变压器技术参数和要求GB/T22072-2008干式非晶合金铁心配电变压器技术参数和要求GB/T25289-201020kV油浸式配电变压器技术参数和要求GB/T25446-2010油浸式非晶合金铁心配电变压器技术参数和要求JB/T10317-2014单相油浸式配电变压器技术参数和要求JB/T3837变压器类产品型号编制方法3术语和定义GB1094.1、GB1094.11、GB20052-2013及GB/T2900.95其他相关标准界定的以及下列术语和定义适用于本标准。3.1变压器能效限定值minimumallowablevalueofenergyefficiencyfortransformer在规定的测试条件下,变压器的空载损耗和负载损耗的允许最高限值。3.2变压器节能评价值evaluatingvalueofenergyconservationfortransformer在规定的测试条件下,评价节能变压器空载损耗和负载损耗的最高值。4技术要求4.1基本要求油浸式变压器技术要求和技术参数应符合GB1094.1、GB/T6451-2015和JB/T3837的要求,油浸式电工钢带铁心变压器还应符合GB/T25289-2010和JB/T10317-2014的要求,油浸式非晶合金铁心变压器还应符合GB/T25446-2010的要求;干式变压器技术要求和技术参数应符合GB1094.11、GB/T10228-2015和JB/T3837的要求,干式非晶合金铁心变压器还应符合GB/T22072-2008的要求。变压器类产品的型号和损耗水平代号编制方法应符合JB/T3837的要求。与各能效等级对应的变压器的空载损耗值和负载损耗值应无正偏差。4.2变压器能效等级变压器能效等级分为3级,标识为:能效1级--NX1、能效2级--NX2、能效3级--NX3,其中能效1级损耗值最低、能效3级损耗值最高。4.3变压器能效限定值电工钢带铁心变压器的空载损耗值和负载损耗值均不应高于表2~表17中能效等级3级的规定。T/CEEIA258—201634.4变压器节能评价值变压器的空载损耗值和负载损耗值均不应高于表2~表22中能效等级2级的规定。5试验方法变压器的空载损耗和负载损耗应按GB1094.1和GB1094.11的要求进行测试。6变压器的能效等级、能效限定值、节能评价值详情见表2~表22——表26kV、10kV级30kVA~2500kVA三相油浸式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级;——表36kV、10kV级630kVA~6300kVA三相油浸式电工钢带铁心无励磁调压电力变压器能效限定值及能效等级;——表46kV、10kV级200kVA~2500kVA三相油浸式电工钢带铁心有载调压配电变压器能效限定值及能效等级;——表56kV、10kV级5kVA~160kVA单相油浸式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级;——表620kV级30kVA~2500kVA三相油浸式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级;——表720kV级5kVA~160kVA单相油浸式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级;——表835kV级50kVA~2500kVA三相油浸式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级;——表935kV级630kVA~31500kVA三相油浸式电工钢带铁心无励磁调压电力变压器能效限定值及能效等级;——表1035kV级2000kVA~31500kVA三相油浸式电工钢带铁心有载调压电力变压器能效限定值及能效等级;——表116kV、10kV级30kVA~2500kVA三相干式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级;——表126kV、10kV级315kVA~2500kVA三相干式电工钢带铁心有载调压配电变压器能效限定值及能效等级;——表136kV、10kV级630kVA~6300kVA三相干式电工钢带铁心无励磁调压电力变压器能效限定值及能效等级;——表1420kV级50kVA~2500kVA三相干式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级;——表1535kV级50kVA~2500kVA三相干式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级;——表1635kV级800kVA~25000kVA三相干式电工钢带铁心无励磁调压电力变压器能效限定值及能效等级;——表1735kV级2000kVA~25000kVA三相干式电工钢带铁心有载调压电力变压器能效限定值及能效等级;T/CEEIAXX—20164——表186kV、10kV级30kVA~2500kVA三相油浸式非晶合金铁心无励磁调压配电变压器能效限定值及能效等级;——表196kV、10kV级5kVA~160kVA单相油浸式非晶合金铁心无励磁调压配电变压器能效限定值及能效等级;——表2020kV级30kVA~2500kVA三相油浸式非晶合金铁心无励磁调压配电变压器能效限定值及能效等级;——表2135kV级50kVA~2500kVA三相油浸式非晶合金铁心无励磁调压配电变压器能效限定值及能效等级;——表226kV、10kV级30kVA~2500kVA三相干式非晶合金铁心无励磁调压配电变压器能效限定值及能效等级;T/CEEIA258—20165表26kV、10kV级30kVA~2500kVA三相油浸式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级能效等级123短路阻抗%损耗水平代号141311额定容量kVA电压组合及分接范围联结组标号空载损耗kW负载损耗kW空载损耗kW负载损耗kW空载损耗kW负载损耗kW高压kV高压分接范围%低压kV3066.31010.5±2×2.5±50.4Dyn11Yzn11Yyn00.0800.505/0.4800.0800.630/0.6000.1000.630/0.6004.0500.1000.730/0.6950.1000.910/0.8700.1300.910/0.870630.1100.870/0.8300.1101.09/1.040.1501.09/1.04800.1301.05/1.000.1301.31/1.250.1801.31/1.251000.1501.26/1.200.1501.58/1.500.2001.58/1.501250.1701.51/1.440.1701.89/1.800.2401.89/1.801600.2001.85/1.760.2002.31/2.200.2802.31/2.202000.2402.18/2.080.2402.73/2.600.3402.73/2.602500.2902.56/2.440.2903.20/3.050.4003.20/3.053150.3403.06/2.920.3403.83/3.650.4803.83/3.654000.4103.61/3.440.4104.52/4.300.5704.52/4.305000.4804.33/4.120.4805.41/5.150.6805.41/5.15630Dyn11Yyn00.5704.960.5706.200.8106.204.58000.7006.000.7007.500.9807.5010000.8308.240.83010.31.1510.312500.9709.600.97012.01.3612.016001.1711.61.1714.51.6414.520001.5514.61.5518.31.9418.35.025001.8316.91.8321.22.2921.2注:对于额定容量为500kVA及以下的变压器,表中斜线上方的负载损耗值适用于Dyn11或Yzn11联结组,斜线下方的负载损耗值适用于Yyn0联结组。T/CEEIAXX—20166表36kV、10kV级630kVA~6300kVA三相油浸式电工钢带铁心无励磁调压电力变压器能效限定值及能效等级能效等级123短路阻抗%损耗水平代号141311额定容量kVA电压组合及分接范围联结组标号空载损耗kW负载损耗kW空载损耗kW负载损耗kW空载损耗kW负载损耗kW高压kV高压分接范围%低压kV63066.31010.5±2×2.5±533.156.3Yd11Dy110.6566.230.6566.920.8206.925.58000.8007.610.8008.461.008.4610000.9448.920.9449.911.189.9112501.1210.51.1211.71.4011.716001.3412.71.3414.11.6814.120001.6115.21.6116.92.0116.925001.9017.61.9019.62.3719.631502.2420.72.2423.02.8023.040001010.53.156.32.7624.62.7627.33.4527.350003.2828.23.2831.34.1031.363003.9131.53.9135.04.8935.0T/CEEIA258—20167表46kV、10kV级200kVA~2500kVA三相油浸式电工钢带铁心有载调压配电变压器能效限定值及能效等级能效等级123短路阻抗%损耗水平代号141311额定容量kVA电压组合及分接范围联结组标号空载损耗kW负载损耗kW空载损耗kW负载损耗kW空载损耗kW负载损耗kW高压kV高压分接范围%低压kV20066.31010.5±4×2.50.4Dyn11Yyn00.3042.610.3042.900.3802.904.02500.3523.080.3523.420.4403.423150.4243.690.4244.100.5304.104000.5124.460.5124.950.6404.955000.6085.300.6085.890.7605.896300.7686.530.7687.260.9607.264.58000.8968.000.8968.891.128.8910001.099.361.0910.41.3610.412501.2511.11.2512.31.5612.316001.5413.21.5414.71.9214.720001.8216.71.8218.62.2718.65.025002.1419.42.1421.62.6821.6T/CEEIAXX—20168表56kV、10kV级5kVA~160kVA单相油浸式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级能效等级123短路阻抗%损耗水平代号141311额定容量kVA电压组合及分接范围联结组标号空载损耗kW负载损耗kW空载损耗kW负载损耗kW空载损耗kW负载损耗kW高压kV高压分接范围%低压kV566.31010.511±5±2×2.52×(0.22~0.24)或0.22~0.24Ii0Ii60.0240.1170.0240.1300.0300.1303.0100.0360.2120.0360.2350.0450.235160.0440.2970.0440.3300.0550.330200.0520.3460.0520.3850.0650.385300.0640.5040.0640.5600.0800.560400.0800.6300.0800.7000.1000.7003.5500.0960.7690.0960.8550.1200.855630.1160.9180.1161.020.1451.02800.1281.130.1281.260.1601.261000.1521.340.1521.480.1901.481250.1841.580.1841.760.2301.761600.2321.920.2322.130.2902.13注1:对低压为2×(0.22~0.24)kV组合的变压器,当低压为(0.22~0.24)kV时,容量减半(并联使用时除外)。注2:对于其它的短路阻抗值,由制造单位与用户协商规定。T/CEEIA258—20169表620kV级30kVA~2500kVA三相油浸式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级能效等级123短路阻抗%损耗水平代号141311额定容量kVA电压组合及分接范围联结组标号空载损耗kW负载损耗kW空载损耗kW负载损耗kW空载损耗kW负载损耗kW高压kV高压分接范围%低压kV3020±50.4Dyn11Yzn11Yyn00.0800.621/0.5940.0800.690/0.6600.1000.690/0.6605.5500.1040.909/0.8640.1041.01/0.9600.1301.01/0.960630.1201.08/1.040.1201.20/1.150.1501.20/1.15800.1441.29/1.230.1441.44/1.370.1801.44/1.371000.1601.56/1.490.1601.73/1.650.2001.73/1.6501250.1921.87/1.780.1922.08/1.980.2402.08/1.981600.2322.29/2.180.2322.54/2.420.2902.54/2.422000.2722.70/2.570.2723.00/2.860.3403.00/2.862500.3203.17/3.020.3203.52/3.350.4003.52/3.353150.3843.79/3.610.3844.21/4.010.4804.21/4.014000.4564.47/4.260.4564.97/4.730.5704.97/4.735000.5445.35/5.090.5445.94/5.660.6805.94/5.666300.6486.140.6486.820.8106.826.08000.7847.430.7848.250.9808.2510000.92010.20.92011.31.1511.312501.1011.91.1013.21.3813.216001.3314.41.3316.01.6616.020001.5617.21.5619.11.9519.125001.8720.01.8722.22.3422.2注1:对于额定容量为500kVA及以下的三相变压器,表中斜线上方的负载损耗值适用于Dyn11或Yzn11联结组,斜线下方的负载损耗值适用于Yyn0联结组。注2:根据用户需要,可提供高压分接范围为±2×2.5%或其它分接范围的三相变压器。T/CEEIAXX—201610表720kV级5kVA~160kVA单相油浸式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级能效等级123短路阻抗%损耗水平代号141311额定容量kVA电压组合及分接范围联结组标号空载损耗kW负载损耗kW空载损耗kW负载损耗kW空载损耗kW负载损耗kW高压kV高压分接范围%低压kV520±52×(0.22~0.24)或0.22~0.24Ii00.0240.1220.0240.1350.0300.1353.5100.0360.2210.0360.2450.0450.245160.0440.3110.0440.3450.0550.345200.0520.3640.0520.4050.0650.405300.0640.5260.0640.5850.0800.585400.0800.6620.0800.7350.1000.735500.0960.8100.0960.9000.1200.900630.1160.9630.1161.070.1451.07800.1281.190.1281.330.1601.331000.1521.400.1521.560.1901.561250.1841.660.1841.840.2301.841600.2322.010.2322.240.2902.24注1:根据用户需要,可提供高压分接范围为±2×2.5%或其它分接范围的单相变压器。注2:对低压为2×(0.22~0.24)kV组合的单相变压器,当低压为(0.22~0.24)kV时,容量减半(并联使用时除外)。注3:对于其它的短路阻抗值,由用户与制造方协商确定。T/CEEIA258—201611表835kV级50kVA~2500kVA三相油浸式电工钢带铁心无励磁调压配电变压器能效限定值及能效等级能效等级123短路阻抗%损耗水平代号141311额定容量kVA电压组合及分接范围联结组标号空载损耗kW负载损耗kW空载损耗kW负载损耗kW空载损耗kW负载损耗kW高压kV高压分接范围%低压kV503538.5±2×2.5±50.4Dyn11Yyn00.1281.08/1.030.1281.20/1.140.1601.20/1.146.51000.1841.81/1.720.1842.01/1.910.2302.01/1.911250.2162.13/2.030.2162.37/2.260.2702.37/2.261600.2242.54/2.410.2242.82/2.680.2802.82/2.682000.2722.99/2.840.2723.32/3.160.3403.32/3.162500.3203.56/3.380.3203.95/3.760.4003.95/3.763150.3844.28/4.080.3844.75/4.530.4804.75/4.534000.4645.17/4.920.4645.74/5.470.5805.74/5.475000.5446.22/5.920.5446.91/6.580.6806.91/6.586300.6647.070.6647.860.8307.868000.7848.460.7849.400.9809.4010000.92010.40.92011.51.1511.512501.1212.51.1213.91.4013.916001.3514.91.3516.61.6916.620001.5917.71.5919.71.9919.725001.8920.91.8923.22.3623.2注:对于额定容量为500kVA及以下的变压器,表中斜线上方的负载损耗值适用于Dyn11联结组,斜线下方的负载损耗值适用于Yyn0联结组。
展开
收起

全部评论

暂无评论

引用:

评论:

S6工作室

上传于:2022-11-24

文档数:328篇

相关文档

相关资讯

相关百科